Introduction of the biological reactor
The biological reactor consists of body, gears, mixing devices, heating devices, cooling devices, seal composition and some corresponding auxiliary equipment: distillation column, condenser, water separator, collecting cans, filters ect. According to the structure features, reactor can be divided into open-type reactor of flush cover, open welded flange-type reactor and the closed reactor three categories.
Features of the biological reactor
Material: SUS304 or S.S.316L
Mixing type: anchor type, frame type or paddle type
Sealing equipment: Mechanical sealing
Heating or Cooling: jacket, half pipe or coil pipe
Heating way: steam heating, electrical heating or heat conduct oil.
Volume: can be made as per customer requirements
Measure: can be made as per customer requirements
Total Volume | 5/7/10L | 10L-2KL |
Vessel | 316L Stainless Steel +Borosilicate Glass | 316L stainless steel |
Stirrer | Top driven or bottom Driven by magnetic Coupling | |
Sterilization | In suit Sterilization(steam source external)or In autoclave | |
Basic Features | Temperature,RPM,PH,DO,Antifoam,Feed,Aeration,Pressure,weight culture medium,weigh feed,Exhaust O2&CO2,Offline Operation:CER,OUR,RO,KLa | |
Advanced Features | Level,Weight Feed,Multi-Feeds, Mehanol&Ethanol,Exhaust O2&CO2 | |
Features | Automatic control and monitor rmp ,temperature,PH,DO,foam,air flow rate,weight exhaust O2&CO2,offline parameter(bacteria number,base,nitrogen,valence)could be input manually | |
with Tail Gas Analysis system (Multichannel) | Measuring;CO2 online (auto) range :0-5%±0.5% | |
Controller | BIOTECH-7000 Technical parameter | |
Parameter | Guideline | Controller data processing function |
pH | Displaying range: 0.00~14.00±0.01 | pH value historical and trend curve analysis Acid, alkali dosage curve analysis |
Antifoam | Automatic PID control and alarm | Antifoam value historical and trend curve analysis Foam error state record |
Rpm | Automatic enactment and control(50~1000rpm±5‰) | Rpm value historical and trend curve analysis Batch report form analysis Keep and deliver data |
Temperature | Temperature of cooling water: +5℃-65℃±0.2℃ | Temperature value historical and trend curve analysis Batch report form analysis Keep |
Feeding | PID automatic enactment and control | Feeding value historical and trend curve analysis |
Pressure | Manual control, instrument display | |
Air flux | Manual control, instrument display |